Honda’s Gurugram Plant Now Tracks PM2.5 and PM10 On Site
NEW DELHI. Honda Motorcycle and Scooter India’s Gurugram facility now measures and records its own PM2.5 and PM10 readings. An outdoor display board shows the numbers to people on the premises. SFK Industries installed the system, which is the company’s pitch for on-site monitoring at a time when local industry compliance is under scrutiny.
The unit, model AAQMS-M01, uses light scattering to read particulate matter. It measures PM2.5 from 0 to 500 µg/m³ and PM10 from 0 to 1,000 µg/m³, both at the same time. Its resolution is 1 µg/m³, its accuracy is ±5% of full scale, and it responds in under 30 seconds. The manufacturer is Engineering & Environmental Solutions Pvt. Ltd.
Operators choose between two modes. Survey mode is for spot checks. Recording mode saves each reading with a location ID, date and time, at intervals of 5, 15 or 30 minutes. Staff can pull the data into Windows software or open it in MS Excel. The unit has RS232 and USB ports, plus GPRS connectivity to a cloud server. Its dust-proof casing and wall-mount design suit outdoor use.
The display board is a multi-colour P10 unit with a black body. It shows at least eight lines of text, with characters starting at 80 mm. It is rated for ambient temperatures up to 55°C and runs on 230 VAC supply.
Nitin Kaushal, Founder and CEO of SFK Industries, framed the installation around access to data. “Air quality readings are useful only when they can be tracked,” he said. He called the project a combined measuring and display system and said the company would take on similar industrial requests.
The timing matters for Gurugram. The city fails to meet national air quality standards and is part of the government’s non-attainment city list. A Tribune investigation found that more than 75 per cent of industries in Gurugram and Faridabad had not installed pollution control devices despite a mandate. Monitoring is central to closing that gap. Regulators want industries connected to online systems that send live emission data to the pollution control boards.
The release does not say whether the Honda data goes to regulators or only stays on site. It also does not name the Honda plant’s emission sources, nor the regulators who reviewed the installation.